How to estimate flow and head
These two figures help narrow the initial selection.Flowis the volume of water required per hour (m³/h);Headis the energy expressed as an equivalent height of water (m).
FlowEstimate from demand: draining a 30 m³ tank in two hours requires 15 m³/h. For domestic supply, estimate demand at the outlets; 0.6 m³/h per tap is an illustrative value that needs checking against actual use.
Head is not just building height. Pipework resistance and required outlet pressure also contribute:
+ Pipe losses(rough example: 5–10 m per 100 m of pipe; actual losses depend on the pipe and flow)
+ Required outlet pressure(approximately 1 kgf/cm² of pressure corresponds to 10 m of head)
Example: a basement-to-rooftop installation has about 20 m of vertical lift and 40 m of pipe with several bends. Including pipe losses could bring the required head to around 30 m rather than 20 m. Verify the actual system losses before selecting the pump.