Selection guide / common questions

Based on 20 years of store experience Understand the essentials before choosing a model

These are the questions customers have asked at our counter over the years. If you still need help, call us with your application and duty requirements.

01 · The most common question

How to estimate flow and head

These two figures help narrow the initial selection.Flowis the volume of water required per hour (m³/h);Headis the energy expressed as an equivalent height of water (m).

FlowEstimate from demand: draining a 30 m³ tank in two hours requires 15 m³/h. For domestic supply, estimate demand at the outlets; 0.6 m³/h per tap is an illustrative value that needs checking against actual use.

Head is not just building height. Pipework resistance and required outlet pressure also contribute:

Total head = Static lift(vertical distance from the water level to the outlet)
  + Pipe losses(rough example: 5–10 m per 100 m of pipe; actual losses depend on the pipe and flow)
  + Required outlet pressure(approximately 1 kgf/cm² of pressure corresponds to 10 m of head)

Example: a basement-to-rooftop installation has about 20 m of vertical lift and 40 m of pipe with several bends. Including pipe losses could bring the required head to around 30 m rather than 20 m. Verify the actual system losses before selecting the pump.

Common mistake Selecting only by building height can leave too little head to reach the rooftop. Allow for calculated system losses and an appropriate margin.
02 · Power supply

220 V or 380 V?

Check the supply at the installation. Homes and small shops in China commonly use 220 V single-phase; factories, construction sites and irrigation installations often have 380 V three-phase.

220 V single-phaseCommon for domestic and smaller installations. The catalog includes many models up to 2.2 kW; higher starting currents require careful supply checks. Model codes often include D, as in QDX, WQD and 50WQD.
380 V three-phaseCommon for higher-power industrial applications. Three-phase versions in these series often omit D, for example QX, WQ and 50WQ. Confirm the actual nameplate voltage and frequency.

A similar specification may be offered in both versions with only one letter different.Always confirm the power supply before purchasing. Connecting a motor to the wrong voltage can prevent operation or cause damage; electrical connections must match the nameplate and be checked by qualified personnel.

03 · Pipework

Choosing a connection size

Connection size describes the inlet or outlet diameter. Common nominal equivalents are DN50 / 2 inches, DN80 / 3 inches and DN100 / 4 inches. Check the actual connection standard and dimensions.

The key principle is:Choose pipe size against flow, rather than motor power alone. Undersized pipework increases velocity and resistance and can contribute to vibration or cavitation. Larger flows generally need larger pipes.

Illustrative sizing rangesExamples for initial discussion: up to 10 m³/h with DN50; 10–30 with DN65–80; 30–60 with DN100; and above 100 with DN150 or larger. These ranges are not a substitute for hydraulic calculations.
Existing pipeworkIf pipework is already installed, provide its size and layout when selecting the pump. Include the additional losses from any reducers or transitions in the calculation.
04 · Pump arrangement

Submersible or self-priming?

The main distinction iswhether the pump is submerged or installed above the liquid。

Submersible pumpThe unit operates in the liquid, saving floor space and avoiding a separate suction-priming arrangement. Maintenance normally requires lifting the pump; cable condition is important. Confirm the model for deep-water or sewage-sump use.
Self-priming pumpInstalled above the liquid for easier inspection and maintenance. A key constraint is thelimited suction lift. Around 4–5 m is a common initial reference, but the exact limit depends on the model and conditions. Initial filling is normally required; follow the manufacturer instructions.

Consider the vertical distance from the liquid level to the pump. If it ismore than about 5 m, review submersible or submerged alternatives. Confirm actual suction limits and liquid compatibility; maintenance access and whether the motor should be kept outside the liquid also affect the choice.

05 · Sewage handling

Standard, cutting or mixing sewage pump?

Start with the composition of the liquid and solids.

Standard WQA large-passage impeller can handle solids within the specified passage size. Discuss the model for domestic sewage, rainwater or site drainage.
WQG / QGWQ cutting typesA cutting mechanism processes material before discharge. Forfibers, hair, rags, plastic film or sanitary waste,consider a suitable cutting configuration and confirm its permitted solids with the manufacturer; these materials can block an unsuitable pump.
JYWQ mixing typesA bottom-mounted mixing device agitates settled material. Discuss suitability for septic tanks, settling tanks or livestock wastewater against the actual solids and viscosity.
Practical experience For sewage receiving toilet waste, review the need for a cutting configuration. Blockage removal and downtime can cost more than the initial price difference.
06 · Boreholes

Measuring a borehole and choosing a pump

Begin by measuring these three requirements accurately.

① Borehole internal diameter This determines whether the pump fits. The pump must have sufficient clearance within the actual borehole.
  For a nominal 4-inch borehole (about 100 mm), review the 100 series(listed outside diameters around 98–100 mm; confirm installation clearance)
  For 5–6-inch boreholes, review the 130 / 135 series(listed outside diameters around 127–144 mm)

② Dynamic water level The stabilized water level while pumping, rather than the static level.
③ Required total head = dynamic water-level depth + elevation above ground to the outlet + pipe losses

Installation often places the pump below the dynamic water level with clearance above the bottom to avoid sediment. The 1–3 m submergence and 1 m bottom-clearance examples must be checked against the model instructions and well conditions.

Measure before ordering Measure the borehole or provide the existing pump dimensions before ordering. An oversized unit that cannot be installed wastes time and freight costs.
07 · Fire pumps

Reading fire pump model codes

Fire pump model codes follow a defined format. For example, XBD7.0/20G-L:

XBD Fire pump set
7.0 Rated pressure: 0.70 MPa (approximately 70 m of water head)
20 Rated flow: 20 L/s (multiply by 3.6 to obtain 72 m³/h)
G Single-stage · GDL Vertical multistage
L Vertical · W Horizontal
Follow the approved project specification Fire protection procurement requires review against the approved design and applicable certification requirements. Use the specified flow in L/s and pressure in MPa to check the catalog; do not substitute equipment based on a rough estimate.
08 · Model codes

What do model suffixes mean?

Common letters used in SRM model codes are listed below. Confirm the meaning within the specific series:

DOften indicates single-phase 220 V in WQD, QDX and QD model families; corresponding versions without D may be 380 V. Confirm the nameplate.
A / B / CIn centrifugal pump series, these letters can indicate trimmed impeller variants with different flow, head and power. Review the appropriate performance curve.
GCutting versions, as in WQG and QGWQ.JY Mixing configuration.S Stainless steel or cutting configuration, depending on the series.B All-stainless version within the relevant series.
/2 /3 /4Stage count, associated with the number of impellers. Additional stages generally increase head at the specified flow; QD10-80/6 denotes six stages in that model family.
09 · Troubleshooting

Checks when a pump does not deliver water

Review these possible causes in sequence; the first four are common starting points:

1 · Incorrect rotationA three-phase pump may run in reverse and deliver reduced flow. Have qualified electrical personnel isolate the supply and verify phase sequence and the required rotation direction.
2 · Missing priming water / air leakCheck priming requirements for self-priming and centrifugal models. Suction-joint leaks or a leaking foot valve can prevent priming and lead to dry running.
3 · Excessive suction liftReview whether the suction lift exceeds the model limit. Around 5 m is only a preliminary reference; lowering the installation may help, subject to the actual suction conditions.
4 · BlockageThe inlet, impeller or foot-valve strainer may be obstructed. Isolate the power before inspection or cleaning.
5 · Insufficient headWater may discharge but fail to reach the required elevation if total system head was underestimated.
6 · Undervoltage / phase lossLow speed, weak delivery and motor overheating may indicate an electrical problem. Have the supply and wiring checked by qualified personnel.
Safety first Isolate the power before any inspection. Do not touch a submerged pump until electrical isolation has been verified.
10 · Sizing principles

Is buying a larger pump safer?

Not necessarily.Oversizing can increase energy use and operating problems.

A pump should operate within a suitable range around its design duty point. Oversizing can move operation outside the efficient range and contribute to excess flow, overload, vibration or cavitation. An undersized pump may fail to meet demand.

The appropriate approach is toselect against actual duty conditions and review an appropriate margin. A 10–20% allowance is an initial discussion point, not a universal sizing rule. Our catalog tool filters records meeting the entered requirements and sorts by excess capacity; the final choice still needs a pump-curve and system review.

Need help?Describe the task, such as septic drainage, rooftop water supply or a 40 m borehole, and discuss the selection with us.

Still unsure? Contact us

Start with three things:the liquid, the required flow and the delivery height. Our store can help review the remaining details.